Ȩ >Á¦Ç°¼Ò°³

ADVIA 2400

¢º ó¸® ¼Óµµ: 2400 tests/hour, 1800 tests/hour colorimetric, 600 tests/hour ISE

¢º The right balance of speed and efficiency
         The ADVIA 2400 Clinical Chemistry System meets today¡¯s high turnaround-time (TAT) goals with a throughput of 2400 tests/hour. Besides assays for general and specialty chemistries, its menu includes methods for specific protein measurement, drugs-of-abuse testing (DAT) and therapeutic drug monitoring (TDM). Interesting new methods such as Cystatin C, HbA1c with automated sample pretreatment and CardioPhase® hsCRP can now be included into your routine testing. The ADVIA 2400 Clinical Chemistry System can easily be added to laboratory automation systems such as the ADVIA® LabCell from Siemens.

          The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid 2-second probe cycle time maximizes tube speed and test throughput, and combines with the system¡¯s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories

¢º Superior Speed and Productivity
     1) Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads
     2) Rapid, consistent 2-second cycle time
     3) Top-of-class throughput of 200 tubes per hour even when running 3 ISE tests and up to
         9 photometric tests per sample
     4)Automatic Sample Retain technology, auto-repeat, auto-dilution and auto-reflex testing

¢º Automation Ready
     1) Point-in-space aspiration offers connectivity to a track or rack handler without robotics or
         special hardware
     2) Redundant sample loading for built-in backup and easy handling of non-routine samples
     3) Direct sampling from track prevents detaining tubes at analyzer and reduces aliquoting

¢º Minimal Intervention Demands
     1) Minimal-maintenance ISEs
     2) Large onboard reagent capacity and optional concentrated reagents reduce interruptions
     3) No-maintenance 37oC incubation fluorocarbon bath oil
     4) Auto-calibration and auto-QC from refrigerated onboard calibrators and controls
     5) Microvolume technology with 32,000 tests onboard and up to 60 days onboard stability maximizes
         walkaway time
     6)Remote diagnostics and ILQC (Inter-Laboratory Quality Control) options

¢º Exceptional Reliability
     1) Sample integrity check for icterus, hemolysis and lipemia
     2) Sample probe with automatic clot/clog detection, liquid level sensing, short sample detection and
         crash protection
     3) Advances in reagent onboard stability, calibration frequency, interference reduction and assay
         linearity expansion